Leotek Engineering Pvt. Ltd.

Platform for Effortless Access to Ready Mix Spares

Roots Blower Systems

Introduction
Description
Main components

A Roots blower also called a positive displacement (PD) blower, rotary-lobe blower, or roots air blower—is a low-pressure, high-volume air-moving machine. In a concrete batching plant, it supplies pulsed, oil-free compressed air for pneumatic conveying of cement and mineral powders, fluidisation of silo bottoms, and bulker unloading.

Unlike a screw compressor, a roots blower does not compress air internally. It displaces a nearly fixed volume of air per revolution, so its discharge pressure is created by the resistance of the downstream pipeline, silo, filter, and material column.

It generally uses two synchronized lobed rotors rotating in opposite directions inside a close-clearance casing.

Unlike a centrifugal fan, a Roots blower can maintain useful airflow against relatively high system resistance, making it suitable for certain pneumatic conveying and aeration applications.

A typical roots blower package consists of:

  • Two or three-lobe rotary impellers mounted on parallel shafts.
  • Timing gears that keep the lobes synchronised without metal-to-metal contact.
  • Cast-iron or fabricated steel casing.
  • Anti-friction bearings and shaft seals.
  • Belt drive or direct-coupled electric motor.
  • Inlet filter-silencer, discharge silencer, pressure relief valve, non-return valve, pressure gauge, and temperature switches.
  • Base frame, acoustic enclosure, and control panel.

For cement plants, the blower is normally installed as a skid-mounted package with inlet filter, safety valve, check valve, pressure transmitter, and electrical starter/VFD.

  • Component

    Function

    Blower casing

    Encloses the rotating elements and airflow passage

    Twin-lobe or tri-lobe rotors

    Transfer air from inlet to discharge

    Timing gears

    Maintain rotor synchronization

    Shaft and bearings

    Support and rotate the rotor assembly

    Shaft seals

    Limit leakage and protect bearing compartments

    Inlet air filter

    Prevents dust entering the blower

    Inlet / discharge silencers

    Reduce operating noise

    Electric motor

    Provides mechanical drive power

    Belt or coupling

    Transmits power to blower shaft

    Pressure relief valve

    Protects against excessive discharge pressure

    Non-return valve

    Prevents reverse flow where required

    Pressure and temperature instruments

    Monitor operating conditions

    Base frame and guards

    Provide mounting and mechanical protection

Working principle
Two-lobe versus three-lobe blowers
Types of Blower Systems

Simplified conceptual rotor arrangement, not a dimensioned manufacturing drawing.

The operating sequence is:

  1. Air enters through the blower inlet.
  2. The rotating lobes trap volumes of air between the rotors and casing.
  3. These volumes are carried around the casing toward the discharge side.
  4. Air is delivered into the discharge line against the system's backpressure.
  5. Timing gears prevent the rotors from contacting one another under normal conditions.

The blower does not principally compress air internally in the same way as a screw compressor. The pressure rise occurs when delivered air encounters the downstream system pressure.

Feature

Two-lobe blower

Three-lobe blower

Rotor configuration

Two lobes per rotor

Three lobes per rotor

Operating principle

Positive displacement

Positive displacement

Flow pulsation

Typically greater

Typically reduced

Noise characteristics

Depends on design and silencing

Often improved pulsation characteristics

Maintenance

Gears, bearings, seals, filters

Similar maintenance requirements

RMC application

Pneumatic conveying and aeration

Pneumatic conveying and aeration

A three-lobe blower is not automatically more efficient under every operating condition. Performance should be compared using certified duty-point data.

`

Description

Typical application

Two-lobe Roots blower

Conventional twin-rotor design

Pneumatic conveying

Three-lobe Roots blower

Reduced-pulsation rotor design

Pneumatic conveying and aeration

Belt-driven blower package

Motor connected by pulleys and belts

General industrial installations

Direct-coupled blower package

Motor connected through coupling

Fixed industrial installations

VFD-controlled blower package

Motor speed adjusted to process demand

Variable airflow requirements

Acoustic-enclosure blower package

Blower with noise-reduction enclosure

Noise-sensitive installations

A Roots blower can be used in pressure or vacuum service, subject to the specific machine's rating. Not every model is suitable for both.

Materials of construction
Typical operating parameters
Applications in Concrete Plants

The following are common manufacturing choices, not universal specifications. Final material selection depends on the blower design, pressure, temperature, corrosion conditions and manufacturer.

Component

Common MOC

Relevant standards / considerations

Blower casing

Grey cast iron or ductile iron

IS 210, ASTM A48 or ASTM A536, as applicable

Rotors

Cast iron, ductile iron or engineered alloys

Material grade selected for strength and thermal stability

Timing gears

Hardened alloy steel

IS 1570 series or equivalent material specifications

Shafts

Carbon steel or alloy steel

EN8 / C45, EN19 / 42CrMo4 or equivalent

Bearings

Rolling-element bearing steel

ISO 281 for bearing-life calculations

Shaft seals

Elastomeric lip seals or mechanical sealing arrangements

Selected for air, lubricant and operating temperature

Base frame

Structural steel

IS 2062 or ASTM A36

Air piping

Carbon steel

IS 1239, IS 3589 or ASTM piping specifications, as applicable

Fasteners

Carbon or alloy steel

ISO 898-1 for applicable mechanical properties

Coupling / belt guard

Fabricated steel

Applicable machinery guarding requirements

Important: Material standards do not by themselves establish that a completed blower is suitable for a given pressure, speed or temperature. The manufacturer must validate the complete design.

Roots blowers are generally low-pressure, high-volume machines.

The most important specifications for purchasing a blower are:

  • Required inlet airflow in m³/min or m³/h, with reference conditions stated.
  • Required differential pressure in bar or kPa.
  • Ambient temperature and site altitude.
  • Air discharge temperature.
  • Blower RPM and allowable speed range.
  • Motor power, voltage, frequency and efficiency.
  • Noise level and silencer arrangement.
  • Air filtration and sealing requirements.

Continuous or intermittent duty cycle.

Application

How the blower is used

Pneumatic cement conveying

Supplies conveying air for transfer through a pipeline

Fly ash transfer

Moves fly ash between suitable storage or receiving points

GGBS transfer

Provides air for engineered powder conveying systems

Silo aeration

Supplies low-pressure air to suitable fluidising arrangements

Centralized powder handling

Provides air for a shared conveying network where designed

Bulk unloading

Can provide conveying air in installations designed for blower-based unloading

Roots blowers are especially associated with dilute-phase pneumatic conveying. Their suitability for dense-phase systems must be evaluated separately.

Maintenance
Common Blower Problems

Frequency

Inspection / maintenance

Before each operation

Check pressure, unusual noise, leakage, guards and operating condition

Daily

Observe bearing temperature, vibration and discharge pressure, Check Oil level, oil colour & leakage.

Weekly

Check inlet filter restriction, belts, coupling and visible fasteners

Monthly

Inspect silencer condition, safety devices, air leaks and mounting bolts

Annual

Inspect rotor clearances, gear backlash, Check Bearing wear & shaft runout, Verify Motor insulation resistance, Calibrate pressure switches & safety devices &  Repaint external surfaces & inspect corrosion.

As per OEM schedule

Check or replace gear oil, lubricate applicable bearings, inspect seals

Periodic shutdown

Check rotor clearances, timing gears, bearing condition and internal deposits

After major repair

Verify alignment, rotation, clearances and performance before returning to service

The table is a suggested maintenance framework, not a substitute for the blower manufacturer's actual maintenance schedule.

Problem

Possible cause

Corrective action

Low airflow

Clogged inlet filter, incorrect speed or internal wear

Inspect filter, RPM and blower condition

High discharge pressure

Pipeline blockage or excessive system resistance

Stop safely and investigate downstream restrictions

Excessive vibration

Misalignment, bearing wear or rotor damage

Inspect alignment and mechanical condition

High temperature

Excess pressure, inadequate ventilation or lubrication problem

Check operating duty and cooling

Abnormal noise

Gear, bearing, rotor or silencer problem

Shut down if severe and inspect

Motor overload

Excessive differential pressure or mechanical drag

Verify system resistance and drive condition

Oil leakage

Damaged seals or incorrect oil level

Inspect seals and correct lubricant level

Never operate a positive-displacement blower against a closed or blocked discharge. A correctly sized pressure-relief arrangement and protective shutdowns are essential.