A Roots blower also called a positive displacement (PD) blower, rotary-lobe blower, or roots air blower—is a low-pressure, high-volume air-moving machine. In a concrete batching plant, it supplies pulsed, oil-free compressed air for pneumatic conveying of cement and mineral powders, fluidisation of silo bottoms, and bulker unloading.
Unlike a screw compressor, a roots blower does not compress air internally. It displaces a nearly fixed volume of air per revolution, so its discharge pressure is created by the resistance of the downstream pipeline, silo, filter, and material column.
It generally uses two synchronized lobed rotors rotating in opposite directions inside a close-clearance casing.
Unlike a centrifugal fan, a Roots blower can maintain useful airflow against relatively high system resistance, making it suitable for certain pneumatic conveying and aeration applications.
A typical roots blower package consists of:
- Two or three-lobe rotary impellers mounted on parallel shafts.
- Timing gears that keep the lobes synchronised without metal-to-metal contact.
- Cast-iron or fabricated steel casing.
- Anti-friction bearings and shaft seals.
- Belt drive or direct-coupled electric motor.
- Inlet filter-silencer, discharge silencer, pressure relief valve, non-return valve, pressure gauge, and temperature switches.
- Base frame, acoustic enclosure, and control panel.
For cement plants, the blower is normally installed as a skid-mounted package with inlet filter, safety valve, check valve, pressure transmitter, and electrical starter/VFD.
Component
Function
Blower casing
Encloses the rotating elements and airflow passage
Twin-lobe or tri-lobe rotors
Transfer air from inlet to discharge
Timing gears
Maintain rotor synchronization
Shaft and bearings
Support and rotate the rotor assembly
Shaft seals
Limit leakage and protect bearing compartments
Inlet air filter
Prevents dust entering the blower
Inlet / discharge silencers
Reduce operating noise
Electric motor
Provides mechanical drive power
Belt or coupling
Transmits power to blower shaft
Pressure relief valve
Protects against excessive discharge pressure
Non-return valve
Prevents reverse flow where required
Pressure and temperature instruments
Monitor operating conditions
Base frame and guards
Provide mounting and mechanical protection




Simplified conceptual rotor arrangement, not a dimensioned manufacturing drawing.
The operating sequence is:
- Air enters through the blower inlet.
- The rotating lobes trap volumes of air between the rotors and casing.
- These volumes are carried around the casing toward the discharge side.
- Air is delivered into the discharge line against the system's backpressure.
- Timing gears prevent the rotors from contacting one another under normal conditions.
The blower does not principally compress air internally in the same way as a screw compressor. The pressure rise occurs when delivered air encounters the downstream system pressure.
Feature | Two-lobe blower | Three-lobe blower |
Rotor configuration | Two lobes per rotor | Three lobes per rotor |
Operating principle | Positive displacement | Positive displacement |
Flow pulsation | Typically greater | Typically reduced |
Noise characteristics | Depends on design and silencing | Often improved pulsation characteristics |
Maintenance | Gears, bearings, seals, filters | Similar maintenance requirements |
RMC application | Pneumatic conveying and aeration | Pneumatic conveying and aeration |
A three-lobe blower is not automatically more efficient under every operating condition. Performance should be compared using certified duty-point data.
` | Description | Typical application |
Two-lobe Roots blower | Conventional twin-rotor design | Pneumatic conveying |
Three-lobe Roots blower | Reduced-pulsation rotor design | Pneumatic conveying and aeration |
Belt-driven blower package | Motor connected by pulleys and belts | General industrial installations |
Direct-coupled blower package | Motor connected through coupling | Fixed industrial installations |
VFD-controlled blower package | Motor speed adjusted to process demand | Variable airflow requirements |
Acoustic-enclosure blower package | Blower with noise-reduction enclosure | Noise-sensitive installations |
A Roots blower can be used in pressure or vacuum service, subject to the specific machine's rating. Not every model is suitable for both.





The following are common manufacturing choices, not universal specifications. Final material selection depends on the blower design, pressure, temperature, corrosion conditions and manufacturer.
Component | Common MOC | Relevant standards / considerations |
Blower casing | Grey cast iron or ductile iron | IS 210, ASTM A48 or ASTM A536, as applicable |
Rotors | Cast iron, ductile iron or engineered alloys | Material grade selected for strength and thermal stability |
Timing gears | Hardened alloy steel | IS 1570 series or equivalent material specifications |
Shafts | Carbon steel or alloy steel | EN8 / C45, EN19 / 42CrMo4 or equivalent |
Bearings | Rolling-element bearing steel | ISO 281 for bearing-life calculations |
Shaft seals | Elastomeric lip seals or mechanical sealing arrangements | Selected for air, lubricant and operating temperature |
Base frame | Structural steel | IS 2062 or ASTM A36 |
Air piping | Carbon steel | IS 1239, IS 3589 or ASTM piping specifications, as applicable |
Fasteners | Carbon or alloy steel | ISO 898-1 for applicable mechanical properties |
Coupling / belt guard | Fabricated steel | Applicable machinery guarding requirements |
Important: Material standards do not by themselves establish that a completed blower is suitable for a given pressure, speed or temperature. The manufacturer must validate the complete design.
Roots blowers are generally low-pressure, high-volume machines.
The most important specifications for purchasing a blower are:
- Required inlet airflow in m³/min or m³/h, with reference conditions stated.
- Required differential pressure in bar or kPa.
- Ambient temperature and site altitude.
- Air discharge temperature.
- Blower RPM and allowable speed range.
- Motor power, voltage, frequency and efficiency.
- Noise level and silencer arrangement.
- Air filtration and sealing requirements.
Continuous or intermittent duty cycle.
Application | How the blower is used |
Pneumatic cement conveying | Supplies conveying air for transfer through a pipeline |
Fly ash transfer | Moves fly ash between suitable storage or receiving points |
GGBS transfer | Provides air for engineered powder conveying systems |
Silo aeration | Supplies low-pressure air to suitable fluidising arrangements |
Centralized powder handling | Provides air for a shared conveying network where designed |
Bulk unloading | Can provide conveying air in installations designed for blower-based unloading |
Roots blowers are especially associated with dilute-phase pneumatic conveying. Their suitability for dense-phase systems must be evaluated separately.
Frequency | Inspection / maintenance |
Before each operation | Check pressure, unusual noise, leakage, guards and operating condition |
Daily | Observe bearing temperature, vibration and discharge pressure, Check Oil level, oil colour & leakage. |
Weekly | Check inlet filter restriction, belts, coupling and visible fasteners |
Monthly | Inspect silencer condition, safety devices, air leaks and mounting bolts |
Annual | Inspect rotor clearances, gear backlash, Check Bearing wear & shaft runout, Verify Motor insulation resistance, Calibrate pressure switches & safety devices & Repaint external surfaces & inspect corrosion. |
As per OEM schedule | Check or replace gear oil, lubricate applicable bearings, inspect seals |
Periodic shutdown | Check rotor clearances, timing gears, bearing condition and internal deposits |
After major repair | Verify alignment, rotation, clearances and performance before returning to service |
The table is a suggested maintenance framework, not a substitute for the blower manufacturer's actual maintenance schedule.
Problem | Possible cause | Corrective action |
Low airflow | Clogged inlet filter, incorrect speed or internal wear | Inspect filter, RPM and blower condition |
High discharge pressure | Pipeline blockage or excessive system resistance | Stop safely and investigate downstream restrictions |
Excessive vibration | Misalignment, bearing wear or rotor damage | Inspect alignment and mechanical condition |
High temperature | Excess pressure, inadequate ventilation or lubrication problem | Check operating duty and cooling |
Abnormal noise | Gear, bearing, rotor or silencer problem | Shut down if severe and inspect |
Motor overload | Excessive differential pressure or mechanical drag | Verify system resistance and drive condition |
Oil leakage | Damaged seals or incorrect oil level | Inspect seals and correct lubricant level |
Never operate a positive-displacement blower against a closed or blocked discharge. A correctly sized pressure-relief arrangement and protective shutdowns are essential.